We consider the Navier–Stokes equations in a channel with a narrowing and walls of varying curvature. By applying the empirical interpolation method to generate an affine parameter dependency, the offline-online procedure can be used to compute reduced order solutions for parameter variations. The reduced-order space is computed from the steady-state snapshot solutions by a standard POD procedure. The model is discretised with high-order spectral element ansatz functions, resulting in 4752 degrees of freedom. The proposed reduced-order model produces accurate approximations of steady-state solutions for a wide range of geometries and kinematic viscosity values. The application that motivated the present study is the onset of asymmetries (i.e. symmetry breaking bifurcation) in blood flow through a regurgitant mitral valve, depending on the Reynolds number and the valve shape. Through our computational study, we found that the critical Reynolds number for the symmetry breaking increases as the wall curvature increases.

Reduced basis model order reduction for Navier–Stokes equations in domains with walls of varying curvature / Hess, M. W.; Quaini, A.; Rozza, G.. - In: INTERNATIONAL JOURNAL OF COMPUTATIONAL FLUID DYNAMICS. - ISSN 1061-8562. - 34:2(2020), pp. 119-126. [10.1080/10618562.2019.1645328]

Reduced basis model order reduction for Navier–Stokes equations in domains with walls of varying curvature

Hess M. W.;Rozza G.
2020-01-01

Abstract

We consider the Navier–Stokes equations in a channel with a narrowing and walls of varying curvature. By applying the empirical interpolation method to generate an affine parameter dependency, the offline-online procedure can be used to compute reduced order solutions for parameter variations. The reduced-order space is computed from the steady-state snapshot solutions by a standard POD procedure. The model is discretised with high-order spectral element ansatz functions, resulting in 4752 degrees of freedom. The proposed reduced-order model produces accurate approximations of steady-state solutions for a wide range of geometries and kinematic viscosity values. The application that motivated the present study is the onset of asymmetries (i.e. symmetry breaking bifurcation) in blood flow through a regurgitant mitral valve, depending on the Reynolds number and the valve shape. Through our computational study, we found that the critical Reynolds number for the symmetry breaking increases as the wall curvature increases.
2020
34
2
119
126
Hess, M. W.; Quaini, A.; Rozza, G.
File in questo prodotto:
File Dimensione Formato  
1901.03708-1.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: Non specificato
Dimensione 3.4 MB
Formato Adobe PDF
3.4 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11767/117813
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact