We have performed an extensive Voigt profile analysis of the neutral hydrogen (HI) and metal absorption present in a sample of 18 high resolution, high signal-to-noise QSO spectra observed with VLT/UVES. We use this analysis to separate the metal contribution from the HI absorption and present an improved measurement of the flux probability distribution function (PDF) due to HI absorption alone at <z> = 2.07, 2.52, and 2.94. The flux PDF is sensitive to the continuum fit in the normalised flux range 0.8 < F < 1.0 and to metal absorption at 0.2 < F < 0.8. Our new measurements of the flux PDF due to HI absorption alone are systematically lower at 0.2 < F < 0.8 by up to 30% compared to the widely used measurement of McDonald et al. (2000), based on a significantly smaller sample of Keck/HIRES data. This discrepancy is probably due to a combination of our improved removal of the metal absorption and cosmic variance, since variations in the flux PDF between different lines-of-sight are large. The HI effective optical depth at 1.7 < z < 4 is best fit with a single power law, (0.0023 +-0.0007) (1+z)^(3.65 +- 0.21), in good agreement with previous measurements from comparable data. As also found previously, the effect of noise on the flux distribution is not significant in high resolution, high signal-to-noise data.
An improved measurement of the flux distribution of the Lyα forest in QSO absorption spectra: the effect of continuum fitting, metal contamination and noise properties / Kim, T. . S.; Bolton, J. S.; Viel, Matteo; Haehnelt, M. G.; Carswell, R. F.. - In: MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY. - ISSN 0035-8711. - 382:4(2007), pp. 1657-1674. [10.1111/j.1365-2966.2007.12406.x]
An improved measurement of the flux distribution of the Lyα forest in QSO absorption spectra: the effect of continuum fitting, metal contamination and noise properties
Viel, Matteo;
2007-01-01
Abstract
We have performed an extensive Voigt profile analysis of the neutral hydrogen (HI) and metal absorption present in a sample of 18 high resolution, high signal-to-noise QSO spectra observed with VLT/UVES. We use this analysis to separate the metal contribution from the HI absorption and present an improved measurement of the flux probability distribution function (PDF) due to HI absorption alone atFile | Dimensione | Formato | |
---|---|---|---|
mnras0382-1657.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Non specificato
Dimensione
5.44 MB
Formato
Adobe PDF
|
5.44 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.